Insulation R-Value Calculator

Add up the thermal resistance of every layer in a wall or roof assembly and see how much each material contributes to the total R-value.

Total R-value (m²K/W)

2.93

Desglose

U-value (W/m²K)
0.34
Layers counted
2
Biggest contributor
Mineral wool (R-2.5)

Última actualización:

¿Te resultó útil esta calculadora?

FAQ

How do I calculate R-value?

R = thickness ÷ thermal conductivity (λ). 100 mm of mineral wool at λ = 0.040 gives R = 0.1/0.04 = 2.5 m²K/W. Total assembly R-value is the sum of all layer R-values plus thin surface film resistances.

How are R-value and U-value related?

They are reciprocals: U = 1/R_total. U-value expresses heat flow per degree of temperature difference, so lower is better. A wall with R = 5 has U = 0.20 W/m²K.

What is a good R-value for a wall?

Modern energy codes typically require whole-wall R-values of 3–6 m²K/W (US R-20–R-35). The insulation layer itself usually contributes 70–85% of the total, as this calculator's 'biggest contributor' line shows.